Specifications
Yokogawa Panel-mount industrial Paperless Recorder FX1006-4-2-L/USB1/M1
6 Measurement Channels, 5.7 inch(640 x 48), TFT color LCD Display
We can offer you the whole range of Yokogawa products.
Guangzhou Taike Electron Technology Co., Ltd is a leading supplier of dealing with Yokogawa original products for many years, with competitive price, enjoying a good reputation among our clients in Automation and Test & Measuring instruments area.
Email: tekllz @ 163.com
Tel: +86 20 62817729
Fax: +86 20 61216509
The FX1000 is a Paperless Recorder that displays real-time measured data on a color LCD and saves data on a CompactFlash memory card (CF card*1). It can be hooked up to network via Ethernet, which enables to inform by Email and to monitor on Web site as well as to transfer files by using FTP. Also, it can communicate with Modbus/RTU or Modbus/ TCP. It comes with a two, four, six, eight, ten-channel or twelve-channel model. As the input signal, a DC voltage, thermocouple, resistance temperature detector, or contact signal can be set to each channel. The data saved on a CF card or the data transferred via networks can be converted to Lotus 1-2-3, Excel, or ASCII format file, facilitating processing on a PC. Not only this, the Viewer software allows a PC to display waveforms on its screen and to print out waveforms.
Yokogawa Panel-mount industrial Paperless Recorder FX1006-4-2-L/USB1/M1
GENERAL SPECIFICATIONS
Construction
Mounting: | Flush panel mounting (on a vertical plane) Mounting may be inclined downward up to 30 degrees from a horizontal plane. |
Allowable panel thickness: | 2 to 26 mm |
Front panel: | Water- and dustproof: Complies with IEC529-IP65 (excluding side-by-side mounting) |
Input
Number of inputs: | FX1002: 2 channels, FX1004: 4 channels, FX1006: 6 channels, FX1008: 8 channels, FX1010: 10 channels, FX1012: 12 channels |
Measurement intervals: | FX1002, DX1004: 125 ms, 250 ms FX1006, FX1008, FX1010, FX1012: 1 s, 2 s, 5 s |
Inputs: | DCV (20, 60, 200 mV, 1, 2, 6, 20, 50 V, 1-5 V) TC (R, S, B, K, E, J, T, N, W, L, U, WRe) RTD (Pt100, JPt100) DI (Contact input, TTL level) DCA (with external shunt resistor attached) |
Measurement/display accuracy: | Standard operating conditions: Temperature: 23 ± 2°C Humidity: 55% ± 10%RH Power supply voltage: 90 to 132 or 180 to 250 VAC Power supply frequency: 50/60 Hz ± 1% Warm-up time: At least 30 minutes. Other ambient conditions such as vibration should not adversely affect the operation. |
Input | Range | Measurement Accuracy | Digital Display Max. Resolution |
---|---|---|---|
DCV | 1-5 V | ±(0.05% of rdg+3 digits) | 1 mV |
Thermocouple* | K | ±(0.15% of rdg + 0.7°C) –200 to –100°C: ±(0.15% of rdg + 1°C) | 0.1°C |
RTD | Pt100 | ±(0.15% of rdg+0.3°C) 0.1°C | 0.1°C |
* Does not include the accuracy of reference junction compensation
Display
Display: | 5.7-inch TFT color LCD (240 × 320 dots) * A section of the LCD monitor may contain pixels that are always on or off. The brightness of the LCD may also not be uniform due to the characteristics of the LCD. This is not a malfunction. |
Display groups: | Number of groups: 10 Number of channels that can be assigned to each group: Up to 6 |
Display color: | Channel: Select from 24 colors Background: White or black (selectable) |
Trend display: | Layout: Vertical, horizontal, or wide |
Bar graph display: | Direction: Vertical or horizontal (selectable) |
Digital display: | Update rate: 1 sec |
Overview display: | Measuring values and alarm status of all channels |
Information display: | Alarm summary, message summary, memory summary, report, stacked bar graph, status, Modbus status |
Modbus log display: | Displays the login log, error log, communication log (/C2, /C3, and /C7), FTP log (/C7), Web log (/C7), e-mail log (/C7), SNTP log (/C7), and DHCP log (/C7) |
Tag display: | Number of displayable characters: Up to 16 Displayable characters: English, Japanese, and Chinese |
Messages: | Number of displayable characters: Up to 32 alphanumeric Displayable characters: English, Japanese, and Chinese |
Historical display function: | Plays back data from internal memory or external memory media. |
Back light saver function: | LCD back light dims or turns OFF (user selectable) if no keys have been pressed for a specified period (1, 2, 5, 10, 30, or 60 min). |
Data Saving Function
External storage medium: | Medium: CompactFlash memory card (CF card) (on FXs with a CF card slot) |
Internal memory: | Medium: Flash memory Format: FAT32 or FAT16 Capacity: 400 MB Maximum number of files that can be saved: 400 (total number of display data and event data files) Operation: FIFO (First In, First Out) |
Alarm Function
Number of alarm levels: | Up to four for each channel |
Alarm types: | High limit, low limit, differential high limit, difference low limit, high rate-of-change limit, low rate-of-change limit, alarm delay high limit, and alarm delay low limit |
Event Action Function
General: | A particular action can be executed by particular event. |
Number of event actions: | 40 actions can be set |
Security Functions
General: | Login function or key lock function can be set for each key operation or communication operation. |
Key lock function: | On/off and password can be set for each operation key and FUNC operation. |
Login function: | User name and password to login can be set. System administrators: 5 (with access to all operations) Users: 30 (with access to operations based on their user access rights) |
Clock
Clock: | With calendar function (Western calendar) |
Accuracy: | ±50 ppm (0 to 50°C); does not include the delay (1 second or less) that occurs when the power is turned on. |
Batch Function
General: | Data display and data management with batch name, text field function and batch comment function are available. |
Power Supply
Rated power supply: | 100 to 240 VAC (automatic switching) |
Allowable power supply voltage range: | 90 to 132 or 180 to 264 VAC |
Rated power supply frequency: | 50/60 Hz (automatic switching) |
Power consumption: | Max. 45 VA (for 240 VAC power supply) |
NORMAL OPERATING CONDITIONS
Supply voltage: | 90 to 132, 180 to 250 VAC |
Rated power supply frequency: | 50 Hz ±2%, 60 Hz ±2% |
Ambient temperature: | 0 to 50°C |
Ambient humidity: | 20 to 80% RH (at 5 to 40°C), 10 to 50% (at 40 to 50°C) |
-----------------------------------------------------------------